Pyranometers (global radiation sensors) measure global radiation. They are also used as reference instruments due to their measurement precision. The use of this sensor is crucial for measurements with solar-powered applications. It is advisable to use only classified and calibrated pyranometers to ensure accurate results. Adjustable feet and a level allow easy horizontal adjustment.

   
Pyranometer CMP 3

Pyranometer CMP 3

Manufacturer: Kipp & Zonen

Order-No: S61100 (P6341)

Measuring value transmitter for the determination of global radiation. Possible application as albedometer.

  • Classified: „Second Class", WMO + ISO 9060
  • Measuring range: 0 ... 2000 W/m²
  • Sensitivity: 5 ... 20 µV/W/m²
  • Spectral range: 300 ... 2800 nm
  • Non-Linearity: < 2.5% (0 .. 1000 W/m²)
  • Internal resistance: 20 ... 200 Ohm
  • Time constant: 18 s at 95%
  • Temperature range: - 40 ... + 80° C
  • Delivery includes calibration certificate

Downloads

Datasheet(M40)
Datasheet(M32)

   
Pyranometer CMP 6

Pyranometer CMP 6

Manufacturer: Kipp & Zonen

Order-No: S61110 (P6342)

Measuring value transmitter for the determination of global radiation. Possible application as albedometer.

  • Classified: „First Class", WMO + ISO 9060
  • Easy to adjust horizontally due to adjustable feet and a level
  • Measuring range: 0 ... 2000 W/m²
  • Sensitivity: 5 ... 20 µV/W/m²
  • Spectral range: 285 ... 2800 nm
  • Non-Linearity: < 1% (0 ... 1000 W/m²)
  • Internal resistance 20 ... 200 Ohm
  • Temperature range: - 40 ... +80°C
  • Delivery includes calibration certificate

Downloads

Datasheet(M40)
Datasheet(M32)

   
Pyranometer CMP 11

Pyranometer CMP 3

Manufacturer: Kipp & Zonen

Order-No: S61120 (P6343)

WMO- recommended measurement value transmitter for the determination of global radiation

  • Applicable as refence instrument due to its measurement precision
  • Easy to adjust horizontally due to adjustable feet and a level
  • Classified: „Secondary Standard", WMO + ISO 9060
  • Measuring range: 0 ... 4000 W/m²
  • Sensitivity: 7 ... 14 µV/W/m²
  • Spectral range: 285 ... 2800 nm
  • Linearity: < 0.5% (0 ... 1000 W/m²)
  • Internal resistance: 10 ... 100 Ohm
  • Temperature range: - 40 ... +80°C
  • Delivery includes calibration certificate

Downloads

Datasheet(M40)
Datasheet(M32)

   
delta-t sunshine Pyranometer spn 1

72_pyranometer_sunshine_spn1

Manufacturer: Delta-T Devices Ltd.

Order-No: S65100 (P7341)

  • Measurement global (total) and diffuse irradiance in W/m²
  • WMO sun threshold: 120 W/m² direct beam
  • Unique glass dome
  • Wideband thermopile sensors
  • Near ideal spectral and cosinus response
  • Accuracy (cosine corr.) ± 2% of incoming radiation over
    0 ... 90° Zenith angle
  • Diffuse Radiation: ± 8% ± 10 W/m² individual
  • Global (Total): ± 5% ± 10 W/m² hourly average
  • Accuracy: ± 5% daily intervals
  • Non-Linearity: < 1%
  • Measuring range: 0 to >2000 W/m²
  • Spectral range: 400 to 2700 nm
  • Temperature range: - 40 ... +70°

Downloads

Datasheet(M40)
Datasheet(M32)

   
hukseflux Pyranometer sr 11

72_pyranometer_hukseflux_sr11_01

Manufacturer: Hukseflux Thermal Sensors B.V.

Order-No: S63120 (P7351)

"First Class" Solar Radiation SensorApplications: scientific meteorological observations, solar radiation measurements, climate & solar collector testing, building physics. Complies with WMO and ISO Standards

  • Sensitivity (nominal): 15 µV /W/m²
  • Measuring range: 0 ... 2000 W/m²
  • Spectral range: 305 ... 2800 nm
  • Temperature dependence: < 0.1% /°C
  • Temperature range: - 40 ... +80°C

Downloads

Datasheet(M40)
Datasheet(M32)

   
hukseflux Pyranometer lp 02

72_pyranometer_hukseflux_lp02

Manufacturer: Hukseflux Thermal Sensors B.V.

Order-No: S63100 (P7352)

"Second Class" Solar Radiation Sensor
Applications: general meteorological observations, solar radiation measurements, climate & solar collector testing, building physics. Complies with WMO and ISO Standards

  • Sensitivity (nominal): 15 μV /W/m²
  • Measuring range: 0 ... 2000 W/m²
  • Spectral range: 305 ... 2800 nm
  • Temperature dependence: < 0.1% /°C
  • Temperature range: - 40 ... +80°C

Downloads

Datasheet(M40)
Datasheet(M32)

   
silicon Irradiance sensor mt

72_solarirradiancecell

Manufacturer: Mencke & Tegtmeyer GmbH

Order-No.: P6349

Measurement of solar irradiance and temperatures

  • Accuracy at 25°: ± 1.5°C
  • Temperatur compensation: compared to pyranometer within operating range
    -20 ... +70°C and vertical beam of irradiance ± 5%
  • Temperature range -20 ... +70°C
  • Current shunt:
    0.1 Ohm (TC=20ppm/K) @ 1V + 20mA output
    0.12 Ohm (TC=20ppm/K) @ 10V output
  • Non-linearity: ±0.5°
  • Error: ±2.0°
  • Solar cell: Monocrystalline silicon (50 x 33mm)

Downloads

Datasheet(M32)

   

Product-News

AmmonitOR our new online platform is now available for free. To register send us an email at: ammonitor@ammonit.com. With AmmonitOR you can access, manage, monitor and visualise your measurement data, worldwide, around the clock. more

Products Contact

Henner Schienitzki
E: hs (at) ammonit.com

David Strobl
E: ds (at) ammonit.com

Vicente Gutierrez
E: vgv (at) ammonit.com

Max Gräber
E: mag (at) ammonit.com

T: +49-30-6003188-0

Partner Contact

Contact a partner of your choicel
Partner Contact