Impact of Measurement Errors on AEP Calculation

Temperature and air pressure significantly affect the AEP (Annual Energy Production). Hence, according to IEC 61400-12-1 temperature and air pressure have to be measured in a wind measurement campaign.

Wind power is linear proportional to the invers of temperature 1/T (in Kelvin). At 15°C, 1°C error on temperature measurement induces 0.35% error on AEP. The standard IEC 61400-12-1 specifies the relation where the sensitivity factor for temperature is cT,i Pi / 288.15 K.

Therefore IEC 61400-12-1 requires measuring air pressure and temperature.

Show / hide physical background details

The impact of humidity on AEP might be significant if air temperature is high. At sea level and at air temperature of 20°C, air density varies 1.2% between 0 … 100% humidity. It varies 2.0% at 30°C and 4% at 40°C. At high temperatures the IEC recommends to measure the humidity, as well.

  

How is your measurement campaign?

Measurement data complete?
Data quality good enough for MEASNET?
Power supply okay?
Battery voltage satisfactory?

Just ask AmmonitOR to get the latest status of your remote measurement campaign. more

Product Downloads

Product Brochures
Data Sheets
Manuals
Test Reports

Download Acrobat Reader here

Our Sales Team

You want to know more about our products and measurement systems? Contact our sales team on:

E: This email address is being protected from spambots. You need JavaScript enabled to view it.
T: +49-30-6003188-0

Support

Technical questions?
Please contact our support team:

E: This email address is being protected from spambots. You need JavaScript enabled to view it.
T: +49-30-6003188-0

 

Our Partner Network

Our partners represent Ammonit in many different countries.
Find an Ammonit Partner close to your region.