Prevent loss of system configuration when settings are changed.
If the "Delete all measurement data" process is interrupted, it will now be resumed.
Allow changing sensor model when only one requires a calibration table.
Ensure sensor helper loads for unknown sensor models.
Improved robustness against RS485 data corruption for ASCII protocols.
Improved memory usage for CSV generation with RS485 sensors.
Fix endianness for Galltec Thermo-Hygro KPC MS.
Fix Lufft WS 502 implementation.
Fix DHI formula in Evaluation helper.
Fix table sorting on clicking the header in the sensor list and other pages.
Fix statistics calculation for 'Thies FCA X - ASCII' and 'Vaisala WMT700 NMEA'.
![]() | Warning |
|---|---|
You must delete and regenerate older files to correctly perform the statistics calculation. |
Introduce a timeout for SCP communication.
Fix graphical issue in the web interface in Chrom(ium) versions 87 and up.
Fix rounding problem for negative values.
Enhanced startup system storage clean-up function for very large amount of CSV files
New IDS-20 Icing measurement system from Sommer Messtechnik
![]() | Note |
|---|---|
Newly ordered data loggers get a completely new software release, Meteo-40 plus Version 2.0.0 or better, which has the following benefits:
For further Information, please contact our sales team. |
Fix high count statistic for potentiometric wind vanes when combined with several RS485 sensors
Add Lufft WS 502 with solar irradiance
Add Lufft WS 300
New Thies FCA X anemometer implementation for one-step calibration
Enhance performance for very large amount of CSV files
Fix EE071 Hygro-Thermo over RS485 implementation
Add body temperature value to the values read by Hukseflux pyranometer SR30, fix the solar irradiance values
New incoming long wave radiation Ein for pyrgeometers
Fix generate statistics if secondary statistics active and evaluations from Evaluation Helper configured
New DustIQ sensor implemented
Fix problem with resetting tunnel name to tunnel.ammonit.com in some cases
Add maintenance option to automatically delete oldest files in case of system storage shortage
Register if CSV statistics files were copied to USB flash-drive
Fix connect more than one Meteo-40 Modbus RTU slaves (SCADA) to the same RS485 bus
Add option to allow global access to SCADA server
![]() | Warning |
|---|---|
If you use SCADA over USB-Modem you must allow global access! |
More than one client IP addresses allowed for SCADA Modbus TCP
Fix user interface for set date/time over NTP
Fix save and send test email action
New dew point formula in evaluation helper
Fix start recording over LCD
Increase reliability of SCADA stored data request and summary statistic
New solar sensors pyranometer MS-40, pyrheliometer MS-57 and pyrgeometer MS-202
Connection of pyranometer MS-80A over shunt available
Fix TWS100 parser
New Plane of Array irradiance formula in evaluation helper (replaces effective irradiance)
New Soiling Ratio Isc index formula in evaluation helper (replaces Soiling Ratio)
![]() | Warning |
|---|---|
If you had already configured Soiling Ratio evaluations, you will have to configure them again! |
Fix Soiling Loss Index formula in evaluation helper
New sensors type Weather Station in Sensor Helper
New TWS100 integrated dust monitoring station
New Thies Hygro-Thermo compact over RS485
New NRG 200M Wind Vane with configurable slope
New Ampere meter in sensors list for easier configuration of the I-U Conversion Box
New Ampere meter formula in Evaluation Helper for Gantner modules used with Ammonit Soiling Kit
Separated save and send/copy test file for Communication Email/AmmonitOR/Copy
Fix double email, broken in 1.7.12
Thies barometer can be connected to counter input
Thies FCA X automatic request can be deactivated
Remove CMA 11 albedometer from list, can still be configured as two CMP 11
Fix Pyranometer Li-Cor LI-200SZ formula (broken in 1.7.16)
New formula for albedo in Evaluation Helper
New CMA 11 albedometer
New formula for diffuse horizontal radiation (DHI) in Evaluation Helper
Thies FCA X wind speed available with Thies protocol
Thies FCA X - Modbus RTU plain version for connecting more than four sensors to RS485-M
Thies FCA X inclination extended version over Modbus RTU
Fix out of range values in Thies 10-bit protocol for Dx channels
Fix evaluations missing in snapshots
Fix Silicon Irradiance Sensor SiS-13TC-T irradiance formula
Fix SCADA Modbus Register Map field order for Date/Time
Fix request hardware ID from Thies anemometer FCA X
Fix configure other sensors if no switch available
Fix RS485 Modbus RTU sensors signed long values parser
Fix parser for SMP10 over RS485-M
Fix pyranometer solar irradiance negative values for newly configured sensors
New Pyranometer MS-80A in sensor helper
New EE071 Humidity and Temperature Probe in sensor helper
Fix
Secure FTP
Change in CSV files header for internal temperature 'T' to 'T;Avg'
New sensor EKO MS-60M RS485 pyranometer
New sensor EKO M-Box RS485 Modbus RTU adapter for pyranometer
Don't send snapshot if not explicitly configured
Fix automatic system storage clean-up for already sent CSV statistics files (see Section 6.3, “Statistic Data Files”)
New sensor EKO MS-80M RS485 pyranometer
New sensor EKO ML-01 pyranometer
New EC-10 Decagon soil moisture sensor
Add RS485 8 Hz measurement for one sensor
Add
Secure FTP as method to transfer files, additional to
SCP and
FTP,
SCP is still the recommended method
Do not show or log complete login IP address, for data protection
Fix RS485 sensors telegram freezes
New Thies Clima US VDTHP
Fix SDI-12 (broken in 1.7.12)
Fix save SCP (broken in 1.7.12)
Fix Meteo-32 stream map
New download SCADA Modbus registers table as CSV available
New Gill MaxiMet GMX600 weather station
New ultrasonic flow meter KUF2000
New Hygro/Thermo CS215 over SDI-12
Fix period measurement
Allow empty Gateway and DNS server for LAN configuration
Allow use of Switch Manager only with timer
Support two microphones for SM3BAT
Performance enhancement for actions if CSV files not required, e.g. send camera images
Automatically activate period channels on Meteo-40 M and Meteo-40 L
Add purely linear formula for NRG and Generic anenometers
New Vaisala WMT700 NMEA MWV
New Datasol MET Reference Cell
Fix SMP10 pyranometer Modbus registers
Improve email layout
Minor error connections
Meteo-32 stream map includes ZephIR Live data
Enhance CSV files generation reliability
Switch manager supports timer with two user-defined timeframes
Support 2nd, 3rd, and 4th statistical moment (variance, skewness, kurtosis)
Fix statistics interval value written in secondary and tertiary CSV files
Add system storage level to data snapshots
New lightning detector SkyScan SG1000
New Duty Cycle and Pulse Width measurement
Fix some problems when UI not in English
Fix files selection when "start date" parameter used
Fix switch manager label not shown in switches table
New Song Meter SM3Bat Detector
User interface usability enhancements
Allow delete empty Gust data files
New refresh camera image button
Increased MARS stability
Fix CSV file generation, which broke in 1.7.7 in some cases
More updates of UI translation
Fix SDI-12 allowed address range
Fix Modbus RTU sensors configuration migration
Fix recording off after upgrade
Update of UI translation
Add internal V, I and T to Evaluation Helper
Fix source data access for certain RS485 serial settings
Fix internal voltage and temperature available in Switch Manager
Always reduce online traffic when logged in, not only for satellite connections
Fix USB flash drive source data download
Deactivate Gusts files generation if no trigger evaluation configured
New Reflectometer CS650 over SDI-12
New Wind Direction Potentiometric formula in Evaluation Helper
Fix delete evaluations from evaluation helper
Fix compressed files download as Viewer
Selection of individual files for redundant send/copy possible with 'Mark as not sent'
Fix invalidate CSV files
Replace "formula_params" with "params" key in CSV files footer
Fix data logger name encoding error in SCP
Allow fine-grained sending of CSV files
![]() | Warning |
|---|---|
If you already have secondary and/or tertiary CSV files configured, you must explicitely switch on sending to AmmonitOR, by email, or to a file server now! |
Additional RS485 master speed: 1200 bps
Sign all data by default
Support signing and encryption of log and config files for server copy and USB flash drive copy
The comma (",") is not allowed in the data logger name anymore
Fix ZephIR evaluations for more than one height
Effectively turn USB modem switch off, even if no USB modem is connected
Set switch state over display is per default available
Manufacturer administration can be manually started over UI
Newly produced data loggers have individual UI certificates
Fix data logger name encoding error in snapshots and test email
New ZephIR Live data
New Gill Wind Master M3
Fix evaluation type for Gantner modules
Support secondary and tertiary CSV statistics files
New data types with 8-bit exponent selectable for modbus sensors
New Atonometrics RDE300
Evaluation type and unit can be configured for all sensors of type 'Other Sensor'
Enhanced performance for SCADA stored data request
Fix evaluations using GPS location
Provide default WLAN passphrase for newly produced data loggers
Fix wrong time-stamp in CSV files if summary statistic configured
New formulas in Evaluation Helper
Fix live data evaluation for Thies Clima sensor
New Gill Wind Master 3D Ultrasonic XYZ coordinates
Support period measurement on counter channels C5, C6, C11, and C12 for newly produced Meteo-40, available as P1, P2, P3, and P4
Fix switches state shown in display
Fix ultrasonic sensors wind speed linear formula
![]() | Warning |
|---|---|
In case you are using ultrasonic sensors and version 1.6.2, you must delete and regenerate all files generated with this version! |
Fix SCADA stored data request
Allow deletion of multiple selected statistics files
Fix a problem with source data memory overuse if a switch is associated to a sensor
Fix missing latitude and longitude in CSV and admin page when using GPS
Add date and time of last GPS fix in CSV statistics file as
gps_fix
Use function code 4 for Iskra MT540 input registers
Fix SCADA Modbus write to holding registers selection
Switch manager supports inverted logic
Increased robustness for RS485 Thies communication
RS485 serial console representation enhancements
New Thies 3D Ultrasonic XYZ coordinates
New RS485 Master serial console
New RS485 sensor SMP10 pyranometer
Record status byte for Thies Ultrasonic 2D and 3D
Fixed send statistics CSV per email if Gust data active
Include SCADA status in Information site
New set one switch over SCADA using Modbus write single coil
Fixed set switches OFF over SCADA
Fixed request stored data over SCADA
Fixed sending of snapshot data to AmmonitOR, broken in 1.6
Fixed unexpected tunnel connection if SMS active
Fix tunnel connection fails on action execution if another action running
New solar zenith angle in evaluation helper
Allow Mosbus RTU broadcast address '0' for sensors
Slope for ultrasonic sensors wind direction available
Fix SiS-13TC-T sensor irradiance not available
Default connection (Ethernet/Modem) is shown in capital letters (uppercase)
Add support for Met One 014mini anemometer
Optionally create gust data files
Include internal voltage and temperature in Switch Manager lists
Add data snapshot to email and server copy
Add slope and offset for 3D ultrasonic sensors vertical wind speed
Update provider helper with current mobile providers and APNs
Fix custom evaluations: allow any input evaluation and not only evaluations of type "other"
Data logger is prepared for later upgrades via USB flash memory
Fix easy cleanup for SCADA registers tables
Increase backlight time for Meteo-40 Revision D from
5 s to
15 s, and allow Admin to deactivate display backlight
Custom evaluations are ordered in CSV between regular evaluations and channels
Optionally copy camera image to a USB flash drive when sending
Allow Admin and User to view and download data logger files on USB flash drive
Use hPa instead of mbar for newly configured pressure sensors
Fix SCADA stored data request timestamp: use unix time and not logger local time
New summary statistics available over SCADA
New set switches state over SCADA
Allow users starting actions via display (requires setting the permission first)
New covariance evaluation
New generic thermo-hygro 5 V -20–80 °C / 10 V
Maximum and minimum statistics available for internal temperature
Statistics for internal channels can be selected
New sensor MESA WSWD Sonic
Add source data download of complete week
Add function to invalidate all statistics CSV files, that have been sent before
Write in SCADA server holding registers optimized
When setting time, check whether files from later dates exist
Fix close tunnel connection if CECS always on
Fix a harmless, but annoying error message when saving the configuration
User interface: fix related to config file download
User interface: minor performance improvement
Force Encryption now also blocks changes on Email and SCADA, and limits live data to about 2 minutes
New evaluations: Sensible Heat Flux, Turbulence Intensity, Obukkhov stability parameter and Inflow angle
Add function to easily regenerate possibly inconsistent CSV files
Make action handling more reliable
Solve problem with switch "Prevent implicit tunnel activation (only recommended for satellite communication)". The tunnel connection was not disabled after "Action online"
Fix wrong date/time stamps in CSV, in cases when first channel had invalid data
Add option to reduce online traffic when logged in, e.g. for satellite connections
SCADA server write in Modbus store is now an atomic operation
New generic Hygro/Thermo sensor -20–80 °C
New Silicon Irradiance Sensor SiS-13TC-T
Fix SCADA modbus acknowledge writing holding registers
Fix SCADA interval for stored data request
Pyranometer Li-Cor LI-200SZ must be connected to analogue channel
Fix a problem with signatures for newly produced Meteo-40
Enhanced EKO Sun Tracker date, time and location synchronization
Logbook more verbose, i.e. messages about CECS status and actions
Minor UI improvements, e.g. faster web service and data logger icon
Fix a problem with CECS mode not possible to change from LC display
Fix a problem with time setting occasionally not working
Fix CMP10 solar sensor
UI: sow CECS and MARS uptime
Fix false handling of missing digital (TMR) wind vane data
![]() | Warning |
|---|---|
In case you have wrong CSV files, generated from version 1.5 to 1.5.7, you have to remove them and regenerate! |
Rename Heating Manager to Switch Manager
Add switch management by means of wind speed for solar power plants
Fix precipitation scale factor for Meteo-32 Streaming livedata
Fix change switch state with switch manager
Add easy cleanup for SCADA registers tables
Fix Obukov-length CSV header for AmmonitOR
Fix source data download
Fix Silicon irradiance sensor default slope
Add evaluated data to source data view in web interface and to USB flash copy
Add evaluation type and unit to linear equation
Fix ZephIR 300 endianness and statistics
Provide access to stored data over SCADA
Fix ultrasonic wind speed scale factor for Meteo-32 Streaming livedata
![]() | Warning |
|---|---|
In case you are using Meteo-32 Streaming to read wind speed values from ultrasonic sensors, you might need to correct the scale factor at the SCADA master! |
Fix generation of partial CSV files
Minor bug fixes in CSV files generation
Fix action 'Only generate CSV'
Use '---' for invalid value in CSV
Fix statistics when using different measurement rates for counters and digitals
Fix generic windvane evaluation
Fix statistics when using different measurement rates are used
![]() | Warning |
|---|---|
In case you have wrong CSV files, generated from version 1.5 to 1.5.3, you have to remove them and re-generate! |
Fix data snapshots to AmmonitOR
Add hint for BGAN users on LAN page
Add PT100 variant of Galltec Thermo-Hygro Passive CP
More flexible ways of copying files to USB flash drive by date
New ZephIR certified averaged data
Fix CSV File generation with Thies Clima Sensor US
Fix problem with action colliding with midnight reboot
Remove standard cabinets from user interface
New Apogee pyranometer PYR-PA, PYR-SA
Fix RS485 polling rate for Thies Laser Precipitation Monitor
Add self test for digital clock output
More flexible automatic CECS reboot function
![]() | Note |
|---|---|
If you use SCADA or are using Meteo-40 in 24/7 mode, check the setting Automatic CECS reboot option on the administration page after upgrade! |
Add support for sensors:
| EKO Sun Tracker |
| CMP 10 Pyranometer |
| Inclinometer 2-axis SCA121 Level Developments |
| Vento anemometer |
| Galltec Thermo-Hygro with two 4–20 mA |
| ISET Solar Radiation Sensor |
| Generic Thermo/Hygro sensors with voltage outputs |
| Pyranometer Li-Cor LI-200SZ |
New status evaluation in Evaluations Helper
New direction at maximum speed evaluation in Evaluation Helper
Fix active power and obukhov length in evaluation in Evaluation Helper
Fix application of positive and negative slope and offset to Young Propeller Anemometer
![]() | Note |
|---|---|
If you have different slope values for upwind and downwind, it is necessary to regenerate the CSV files! The slope for downwind will be automatically set to a negative value by the data logger. |
Support for SMTPS in addition to STARTTLS for more Email security options
Device Identification available over SCADA
Set date and time over SCADA Modbus communication
CSV stability improvements
Support tilt angle and cardinal direction for SPN1
Improve evaluation view and start messages in LC display
Fix a communication issue, when no AmmonitOR project key is set
Improve GPS reliability
Future upgrades will use HTTPS instead of HTTP, enhancing security
Fix configuring digital channel to power on CECS
Digital signatures refer to uncompressed CSV as canonical, not the compressed files - this might influence your work flow
Fixed a problem with delayed GPS time
GPS location no longer changes configuration
Support for Temperature Sensors 4–20 mA, -30–70 °C and -40–60 °C
Data encryption supported for USB flash drive copy and download
Support for CSPS RSI sensor
New linear equation, active power and wind direction formulas in Evaluation Helper
Heating manager control by means of voltage measurement allowed
Configurable word endianness for RS485 Modbus Sensors
Include solar radiation summary in CSV files
User interface change: New device page with display and USB flash drive settings
User interface change: Encryption and signature now under Administration
Add a option
Connection check in web interface and via LC display
Fix CSV generation with numerous RS485 errors
Fix Young Wind Monitor missing wind direction evaluation
New HMP155 active and passive sensors
Fix tunnel connectivity, when reconfiguring
Reduce SCADA Modbus server response time to
40 ms
Old CSV files get removed on CECS reboot when not enough memory left
Allow custom clipping for humidity sensors
Fixed a problem with encryption when private key is not available
Fixed a problem with sending pictures via FTP
Enhanced RS485 sensors support
Fixed a problem with preventing sending of CSV files to AmmonitOR or file server
Removed unused tilt angle from sensor helper
Fixed UI air density configuration
Fixed a SCADA performance issue
Fixed a problem with display showing "Please wait" for a long time
Fixed a problem with Thies Precipitation Monitor
Fixed a CSV generation error in cases where measurement has been stopped for a day by the user
Data snapshot and camera image can be sent to AmmonitOR now, data snapshot is still experimental
UI: show modem quality bar in LC display and web UI
UI: warn about missing WLAN passphrase
UI: don't show Gantner modules as unknown in LC display
Add Thies Precipitation Monitor
Obukhov length possible with 3D ultrasonics
Enhance memory security esp. for SCADA
Thies Clima Sensor uses wind direction offset for brightness direction
Fixed a problem with SCP sending when data logger name contained non-ASCII characters
Fixed a problem with the SCADA function: In some cases the values were not readable
Fixed a problem with the camera function for data logger with non-ASCII characters in their name
Fixed a problem with the display of values for some RS485 modules
Counter measurement fix: When the clock is set, e.g. by NTP or GPS, under some conditions, the counter value can be wrong. This affected mainly the maximal values
Minor UI fixes
Modem PHS8 is supported
Experimental support for SMS
Complete configuration can be sent to AmmonitOR or via email or FTP/SCP
![]() | Note |
|---|---|
If you don't want to have the configuration file sent to AmmonitOR or via email or FTP/SCP, you have to switch this off in the respective menu. |
New scale factor and data type selection for SCADA measurement values
New Unix Time available over SCADA
Easier connection between PC and data logger using link-local connection
Fixed a problem with CSV generation
Fixed providing sum statistic over SCADA
Digital signature available for newly produced data loggers. Contact Ammonit, if this feature is required on a previously purchased device
The heating manager can make use of an optional voltage as additional heating condition, while the humidity has been made optional
The USB flash drive function is activated with a default password for newly produced data loggers
Factory reset and source data deletion is logged in the logbook
Setting of date/time by GPS, NTP, or manually is logged into logbook
Setting the date via GPS is supported, updating the altitude by GPS is not done anymore
An error in the counters calculation for periods ≠ 1 s has been fixed
Minor user interface changes
Fixed a problem sending images via e-mail
Use new algorithm for wind direction maximum and minimum
Show DHCP state also for Tethering connection
New Thies Laser Precipitation Sensor
Memory sizes are indicated in MiB
Error condition recognition for Gill Wind Master
Enhanced Modbus RTU SCADA server performance
New page for AmmonitOR related configuration
Allow sending data to both AmmonitOR and an FTP/SCP server
New densitiy of moist air evaluation
Fix CSV generation with temperature differential evaluations
Correction for Galltec Thermo-Hygro Passive CP
Allow date limit for file transfer (start date) and reset of send status
Improved check when sending test email
Add experimental support for email encryption
Fix NMEA RS485 telegram parser
Enhance modem communication in respect to disconnection
Enhance clock accuracy
Enhance memory protection
Fix Young Monitor and Tech Sun channel order
Fix erroneous recursive CSV file generation
Support for temperature difference evaluation
More WLAN chips are supported: Atheros AR9271, Ralink rt2800, Ralink rt73
Enhanced UI for accessing source data
Minor error corrections, e.g.
| in respect to USB flash drive, |
| solar evaluations in the LC display, |
| use of non-ASCII characters in email password and data logger name |
| correction of WAV252 and MT32 |
| optimization of SCADA streaming mode |
![]() | Note |
|---|---|
There are some minor, but incompatible changes in this software version. Please check carefully, if one of the changes might affect you. |
New sensors: FarData wind vane, Teknam Thermo-Hygro, Teknam barometric pressure sensor
Enhanced special mode for Meteo-32 wind vane compatibility: No dedicated configuration of Meteo-32 sensors necessary; standard configuration and connection according to manual
Milliseconds in date/time field of statistics file (
.csv) removed; importing software might be configured, if
necessary
Switching of CECS status via status input signal, see .
Format of the
keyfile.txt changed to INI file format; copying of source data to
logbook possible
Minor user interface changes
Speed up and improved robustness of source data download
Speed up some solar evaluations
Enhanced RS485-Sensors error recognition and response
Configurable slope and offset for RS485 ultrasonics horizontal wind speed
Fix RS485-Sensors count statistic when more than one sensor connected
New sensors: Tech-Sen thermo-hygro, Tech-Sen barometric pressure sensor
Correction for status evaluation
Minor user interface changes
New sensors: Setra barometric pressure sensor Model 276 and 278; compatibility for first and second Meteo-32 wind vane
Optimized tunnel traffic
USB connection displayed in status box; data logger name shown in upper right corner
New sensors: Pyranometer SP Lite 2, Gantner e.bloxx A1
Re-enabled reboot at midnight, with exception for SCADA-enabled data loggers
Enhanced flash memory detection
New sensors: Hygro-thermo Galltec KPC MS, passive hygro-thermo Galltec CP, Gantner e.bloxx A3-1 and d.bloxx D1-1, wind vane Vaisala WAV252, Thies precipitation intensity
Support of virtual temperature for Gill wind observer 2D
Better presentation of switches states in live data
Better estimation of sun status for SPN1
User interface enhancements for SCADA
Logbook for registering events
POP-before-SMTP/SMTP-after-POP supported by email function
Better support for USB flash drives
Replacement of tunnel affix by tunnel access code
Download multiple CSV file as ZIP archive
Solved wrong statistics selection (scalar/vector)
Communication enhancements, esp. for satellite modems
Increased memory protection
Support for Sineax Cam Power Meter, e.g. for PCM
Heating manager problem on configuring boundaries corrected
Enhancements in web interface: Statistics calendar
Optional time synchronization via GPS
Heating manager: Temperature and humidity configurable
Support for ISKRA Power Meter, e.g. for PCM
Wind direction offset for ultrasonic sensors added
Timing enhancement for RS485 sensors
Additional route for LAN possible, e.g. for SCADA
Solved sporadic connection failure with modem
Possible wrong timezone corrected, when setting the time manually
Enhancements in web interface for smart phones and small devices
Set default display contrast
Error for Lufft RS485 sensor corrected
Automatic reboot at midnight removed
RS485 serial settings allowed
Further performance enhancements for SCADA
Possible source data corruption problem after second overrun (e.g. after two years) corrected; upgrade must happen before second overrun
Implementation of new "generic" ModBus RTU sensor
Supported temperature measurement using Pt1000 or Pt100 for data loggers with built-in Ethernet interface
Evaluating of virtual temperature for Gill Windmaster Pro 3D, if configured like Thies ultrasonics 2D/3D
Minor user interface corrections
Documenation of heating manager
Performance enhancements for SCADA
Support of data logger with built-in Ethernet interface
New feature: Simple heating manager
Corrected data actualization problem in SCADA
Internet Explorer 8™ and Chrome™ supported
Parallel working of SCADA and modem possible
UI with virtual display keys
Enhanced factory reset
Email sending problem corrected
GPS enhancements
Changes in network shown live in display
CSV files with round time slices
Serial modems work, even if not permanently on
Measurement frequency
⅛s removed
Problem with displaying negative power for pyranometers corrected
Emergency password reset method available by means of Ammonit support for new data loggers
Configuration of longitude, latitude, and altitude, support of KML (e.g. Google Earth™)
USB GPS devices supported
Enhanced user manual
Min and max for wind direction available
Eror when saving sensors corrected
Measurement interruption when upgrading corrected
Measurement range for NRG hygro/thermo sensor corrected
Order of hygro/thermo for Galltec sensor corrected
Corrected error for ICP-CON wind vane module
Enhanced user manual
Detection of under-voltage situation (brown-out) implemented
Configuration of CSD3 optionally with only one voltage channel
Thies wind vane classic with one analog channel supported
SCADA endianess configurable
Overall stability enhancements
More robust CSV creation
Gill Windmaster supported
Power meter GD2000 supported
Virtual temperature Thies ultrasonics 2D/3D evaluated
Turkish language in user interface supported
User interface problem with Internet Explorer™ corrected
Average values for SCADA supported
Gill Wind Obversver is supported
PINs and passwords not visible in the downloaded configuration anymore
Problems with uploading older configuration files solved
CECS mode is saved in the configuration file
New functions to remove all statistics files, all sensors, and for factory reset
Switches in the display shown
Minor changes for upgrade function
Fixing of an potential data corruption error introduced with the last version